SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
50-1096
Sienna
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certied kit is used.
- Do not store or use gasoline or other
ammable vapours and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Open windows/extinguish any open
ame.
• Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbours phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
- Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
WARNING: If the information in this
manual is not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of
life. Installation and service must be
performed by a qualied installer, service
agency or the gas supplier.
Massachusetts installations (Warning): This product must
be installed by a licensed plumber or gas tter when
installed within the Commonwealth of Massachusetts. Other
Massachusetts code requirements: Flexible connector must
not be longer than 36in., a shut off valve must be installed;
only direct vent sealed combustion products are approved for
bedrooms/bathrooms. A carbon monoxide detector is required
in all rooms containing gas-red direct vent appliances. The
replace damper must be removed or welded in the open
position prior to installation of a replace insert.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
OWNERS
MANUAL
Seitenansicht 0
1 2 3 4 5 6 ... 34 35

Inhaltsverzeichnis

Seite 1 - MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Seite 2 - Safety Precautions

Maintenance And ServiceQUALIFIED INSTALLERS ONLYGLASS DOOR REMOVAL:Blower / FanGas & ElectricalTray CompleteBurner Top withGrate AttachedLog Suppo

Seite 3 - Table of Contents

Maintenance And ServiceFUEL CONVERSION:TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLYPlease read and understand these instructions before installi

Seite 4 - Codes And Approvals

12Maintenance And Serviceb) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 12), rotate it counter-

Seite 5 - Specifications

Initial InstallationWARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon

Seite 6

14Initial InstallationCheck draft with a matchor smoke in a " (6 mm)tube located here.MINIMUM FIREPLACE SIZE:Description of Fireplace Dimension

Seite 7 - Operating Instructions

Initial InstallationQUALIFIED INSTALLERS ONLYDIRECT VENT MODEL:WARNING: This appliance has been designed to draw room air for proper heat circulation

Seite 8

16  DV Only: Maximum height allowed for the vent is 35ft(10.67m).Install sealed throat connector or flashing to preventleakage of room a

Seite 9

NOTE: If the Sienna unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-

Seite 10 - Maintenance And Service

18Initial InstallationQUALIFIED INSTALLERS ONLYELECTRICAL REQUIREMENTS:The fan is thermostatically controlled and it will not operate if the a

Seite 11

Initial InstallationQUALIFIED INSTALLERS ONLYGAS LINE CONNECTION: Warning: Only persons licensed to work with gas piping may make the necessary gas co

Seite 12

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Seite 13 - Initial Installation

Initial InstallationQUALIFIED INSTALLERS ONLYCONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE:Direct VentConnector AssemblyFresh AirInlet Cove

Seite 14

21Secondary InstallationFigure 30: Filler panel with trim installation.INSTALLATION OF SURROUND PANEL:The Sienna must have one of the panels installed

Seite 15

Secondary InstallationLOG SET AND EMBER INSTALLATION:NOTE: The logs are fragile and should be handled gently.The placement of the logs is not arbitrar

Seite 16

23Secondary InstallationFigure 34. Third Stage Log Set Installation.Figure 36. Fifth Stage Log Set Installation.Figure 35. Fourth Stage Log Set Ins

Seite 17

Secondary InstallationFigure 37. Sienna complete log set-up with embers burning.NOTE: While the glass is still removed, it is recommended that the gas

Seite 18

25Secondary InstallationREMOVING THE BRICK PANEL:The brick panel set is fragile, handle with extreme care.The brick panel set comes pre-installed. The

Seite 19

Trouble ShootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas c

Seite 20 - 300°F (149°C)

27Parts List- Unit ComponentsReplacement parts must be purchased from an ENVIRO dealer.Reference # Part Description Part #1 120°F Ceramic Fan Temperat

Seite 21 - Secondary Installation

Parts Diagram - ComponentsSIENNA - ComponentsOctober 200428

Seite 22

29Parts Diagram - BurnerSIENNA - BurnerOctober 2004

Seite 23

Table of Contents3Safety Precautions...2Table of C

Seite 24

Parts List - OptionsReference NumberOption DescriptionPart Number1AThe Cottage Trim Kit - Gold 50-5481A The Cottage Trim Kit - Pewter 50-5491A The C

Seite 25 - REMOVING THE BRICK PANEL:

31Parts Diagram - OptionsSIENNA - OptionsOctober 2004

Seite 26 - Trouble Shooting

WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to t

Seite 27

33Warranty4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs

Seite 28 - SIENNA - Components

Warranty19. The paint on the Metal Brick Liner may peel. This is due to the extreme conditions applied to the paint during normal usage. It is not a 

Seite 29 - Parts Diagram - Burner

35Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Seite 30 - Parts List - Options

DIRECT VENT: This type is identied by the sufx DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially

Seite 31 - Parts Diagram - Options

SpecificationsRATING LABEL LOCATION:The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained t

Seite 32 - Warranty

6Specifications151/16"(383 mm)301/2"(775 mm)With Trim333/16"(343 mm)Without Trim33" (338 mm)205/8"(523 mm)223/4"(577 mm)

Seite 33

7WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.PIL

Seite 34

8Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingTURN OFF UNIT:Flip switch to OFF to turn off

Seite 35 - Installation Data Sheet

9Maintenance And ServiceWarning: Failure to position the parts in accordance with this manual, or failure to use only parts specicall