Enviro C-11278 Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Öfen Enviro C-11278 herunter. Enviro C-11278 Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 42
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
50-645
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
DV42DX
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
ame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbours phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas
supplier, call the re department.
WARNING: If the information in this manual is
not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of
life. Installation and service must be performed by a
qualied installer, service agency or the gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or
other ammable vapours and liquids in the vicinity of
this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or
gas tter when installed within the Commonwealth of Massachusetts. Other Massachusetts code
requirements: Flexible connector must not be longer than 36in., a shut off valve must be installed;
only direct vent sealed combustion products are approved for bedrooms/bathrooms. A carbon
monoxide detector is required in all rooms containing gas red direct vent appliances. The replace
damper must be removed or welded in the open position prior to installation of a replace insert.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
Seitenansicht 0
1 2 3 4 5 6 ... 41 42

Inhaltsverzeichnis

Seite 1 - OWNER’S MANUAL

50-645SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R

Seite 2 - Safety Precautions

Maintenance And ServicecLeaning DecoRative suRFaces:Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has b

Seite 3 - Table of Contents

Maintenance And ServicebuRneR anD Fan RemovaL:1. Remove brick liners, see steps 1 to 4 in Secondary inStallation - brick liner reMoval.2. The contro

Seite 4 - Codes And Approvals

12Maintenance And ServiceFueL conveRsion:TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLYPlease read and understand these instructions before instal

Seite 5 - Specifications

Maintenance And Serviceb) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 11), rotate it counter-cl

Seite 6 - Operating Instructions

Initial InstallationQUALIFIED INSTALLERS ONLYintRoDuction:This section of the owner’s manual is for the use of qualied technicians only.

Seite 7

15Initial InstallationQUALIFIED INSTALLERS ONLYcoRneR instaLLation:The dimensions for installing a replace in the corner of a room are given below in

Seite 8

Initial InstallationQUALIFIED INSTALLERS ONLYProtector pad,cement boardand finishingmaterial.Do not tilehigher thanthis ledgeCement boardTileProtector

Seite 9

173½" (89mm)8" (203mm) mantelCombustiblesCement BoardDV42DX10"(254mm)12"(305mm)17"(432mm)20"(508mm)8" (203mm) mante

Seite 10 - Maintenance And Service

1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National Fu

Seite 11

Flue Pipe AdaptorWall FramingWall ThimbleFire StopExhaust 4" Flex PipeCombusion Air 6 5/8" Flex PipeWire SpacersHorizontal Vent Termination1

Seite 12

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances mu

Seite 13

9. Install the ex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect on

Seite 14 - Initial Installation

21Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).Direct Vent GSDirect-Temp Secure Vent Ameri Vent DirectDescripti

Seite 15

22Initial InstallationQUALIFIED INSTALLERS ONLYventing:This replace has been tested and certied for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS”

Seite 16

543210' (0m)0' (0m)1' (0.31m)4' (1.22m)4' (1.22m)8' (2.45m)10' (3.06m)20' (6.11m)30' (9.17m)Vent Restrict

Seite 17

Wall framingHorizontal wallterminationWall thimblefire stopExhaustflex pipeCombustion airouter pipeElbowInitial InstallationQUALIFIED INSTALLERS ONLYh

Seite 18

25Initial InstallationQUALIFIED INSTALLERS ONLYStep 3. To install the Round Support Box/Wall Thimble in a at ceiling, cut a 10 inch (25.4 c

Seite 19

Initial InstallationQUALIFIED INSTALLERS ONLYSTEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should

Seite 20

27NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet

Seite 21 - 8” pipe, adjustable

For the rst 24 inches (610 mm) of ducting, ½ inch (13 mm) of clearance is required. After 24 inches (610 mm), the duct can be run w

Seite 22

29Initial InstallationQUALIFIED INSTALLERS ONLYeLectRicaL RequiRements:The replace must be electrically connected and grounded in accordance w

Seite 23

Table of Contents3Safety Precautions...2Table of Co

Seite 24

Initial Installationgas Line connection anD testing:WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to t

Seite 25

31Secondary InstallationbRicK LineR RemovaL:There are two (2) different brick liner sets; the ceramic set that comes with the unit or the optional cas

Seite 26 - Dimension ‘H’ obtained

Secondary InstallationRight LogFigure 44: Shows the back log plus the two (2) small log twigs. Put the large back log in rst, mak

Seite 27

33Figure 48: Final Log Set Arrangement with Embers.Left LogCenter LogSecondary InstallationFigure 49: DV42DX Burning.Figure 47: Fourth Stage Log Se

Seite 28

TroubleshootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas co

Seite 29

35Parts List - ComponentsReference NumberDescription PartNumber1 120°F (49°C) Ceramic Fan Temperature Sensor EC-0012 S.I.T. Nova Valve Convertible 50-

Seite 30

Parts Diagram - Components913151416641781212117103185DV42DX - ComponentsNovember 200436

Seite 31 - Secondary Installation

37Parts List - OptionsReference NumberOptionsPart Number1The Lodge - Painted Charcoal Face With Plated Brushed Nickel Louvres & Knobs50-534The Ma

Seite 32

Parts Diagram - Options1234 5386 7

Seite 33

39WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to

Seite 34 - Troubleshooting

4DIRECT VENT ONLY: This type is identied by the prex DV. This appliance draws all of its air for combustion from outside the dwelling, through a spe

Seite 35 - Parts List - Components

Warranty4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs o

Seite 36 - Parts Diagram - Components

4120. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials.

Seite 37 - Parts List - Options

42Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Seite 38 - Parts Diagram - Options

SpecificationsINSTALLATION OPTIONS:• Parallel to a wall or placed in a corner • With a oor hearth or raised up the wall• Ducting to other rooms

Seite 39 - Warranty

6WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.PiL

Seite 40

Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. Contact the dealer if there is any concern about t

Seite 41

Operating InstructionsbuRneR Lighting:A) Make sure the pilot is lit.B) Turn gas control knob COUNTER CLOCKWISE to ON.C) Flip the burner switch to O

Seite 42 - Installation Data Sheet

9Maintenance And ServiceRoutine maintenance:At least once a year, run through the following procedures to ensure the system is clean and working prope