CONTROL BOARD FUNCTIONS:
1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger
Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the
feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor
quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On
time to 2 second. This setting is for high-grade fuel only. Push the button until just the number 1
light is on, this is for a three (3) second on time (standard setting).
 


 

 
1
2
3
4
5
6
7
8
 


 

 
2. AUGER PULSE LIGHT: This light will flash
in conjunction with the auger.
3. MANUAL AUGER FEED: If the unit runs
out of fuel, this button can be used to “prime
the auger system”. This button will turn off
after 60 seconds and then must be released
and pressed again.
4. SYSTEM LIGHT: Responsible for signaling
the state of the control board. When the
light is flashing during start-up, the stove
is in an automatic start mode. When the
light is solid, the Heat Level Setting can be
altered.
5. ON/OFF BUTTON: Used to turn the unit
ON and OFF.
6. HEAT LEVEL ADJUSTMENT: When
pressed, will change the heat setting of the
unit from low to high.
7. HEAT OUTPUT INDICATOR: Shows the
present heat output setting.
8. THERMOSTAT SWITCH: Used to set the
unit’s controls to one of three mode settings;
manual, high/low, or auto/off.
Figure 2: Circuit Board Control Panel Decal
AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F
(49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F
(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature
cools. If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND
THE REASONS WHY THE UNIT OVERHEATED.
C) The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum
switch will turn off the auger and the #2 light on the control board will flash.