OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
50-029
ASCOT
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
ame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbours phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas
supplier, call the re department.
WARNING: If the information in this manual is
not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of
life. Installation and service must be performed by a
qualied installer, service agency or the gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or
other ammable vapours and liquids in the vicinity of
this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or
gas tter when installed within the Commonwealth of Massachusetts. Other Massachusetts code
requirements: Flexible connector must not be longer than 36in., a shut off valve must be installed;
only direct vent sealed combustion products are approved for bedrooms/bathrooms. A carbon
monoxide detector is required in all rooms containing gas red direct vent appliances. The replace
damper must be removed or welded in the open position prior to installation of a replace insert.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
Seitenansicht 0
1 2 3 4 5 6 ... 41 42

Inhaltsverzeichnis

Seite 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Seite 2 - Safety Precautions

10Maintenance And ServiceFUEL CONVERSION:Figure 7: Removing valve cap.a) Remove the main burner orice with a  inch deep socket.b) Put a bead of pipe

Seite 3 - Table of Contents

11Maintenance And Serviceb) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 8), rotate it counter-c

Seite 4 - Codes And Approvals

Initial InstallationQUALIFIED INSTALLERS ONLYWARNING: Operation of this heater when not connected to a properly installed and maintained venting syste

Seite 5 - Specifications

13Initial InstallationQUALIFIED INSTALLERS ONLYPLANNING YOUR INSTALLATION:When planning your installation, it will be necessary to select the proper l

Seite 6 - CAUTION:

AADELBCFBBBJMKGHIOpenableFixedClosedOpenableFixedClosedTermination CapAir Supply InletGas MeterGGRestriction Zone(Termination not allowed)NO1 In accor

Seite 7 - Operating Instructions

15Initial InstallationQUALIFIED INSTALLERS ONLYFigure 16: Wire Spacers.it to the inner wall frame using four (4) 1” wood screws

Seite 8

Flue Pipe AdaptorWall FramingWall ThimbleFire StopExhaust 4" Flex PipeCombusion Air 65/8" Flex PipeWire SpacersHorizontal Vent TerminationIn

Seite 9

EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent

Seite 10 - Maintenance And Service

18Initial InstallationVENT RESTRICTOR SETTING:To access restrictor plate, look at the left hand rear corner of the unit. There is a small rectangular

Seite 11

Initial InstallationQUALIFIED INSTALLERS ONLYHORIZONTAL INSTALLATION:STEP 1. Set the appliance in the desired location. Check to determine if wall stu

Seite 12 - Initial Installation

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Seite 13

the cap assembly. It is important that the vent pipe extend into the vent cap a sufcient distance with a minimum of 1” (3.2 cm) overla

Seite 14

21Initial Installation24" (610mm)MaximumHorizontal24" (610mm)MinimumVerticalInsideFinishedCollarWallThimbleHorizontalVentTerminationExterior

Seite 15

elbows necessary to reach from the appliance adapter up through the Round Support Box. Insure that all pipe and elbow connections are in their f

Seite 16

23Initial InstallationQUALIFIED INSTALLERS ONLYVerticalTerminationStorm CollarFlashingRoofing nailsElbow Strapelbow strap down to the roof level, as s

Seite 17

plumber’s tapeconnected towall strapWall strap45° elbows (x2)NailsCeiling firestopCeilingSecond floorUse clearances to asdefined by appliance andvent

Seite 18

25Initial InstallationQUALIFIED INSTALLERS ONLYFREESTANDING DRAFTHOOD ADAPTOR - 50-841:This Drafthood Adaptor is a complete assembly and is ready to 

Seite 19

The minimum clearance to combustibles is 6” (150 mm) when using single wall venting and 1” (25 mm) when using “B-vent” venting.We strongly recommend

Seite 20

27Initial InstallationAUTOMATIC SAFETY SHUT DOWN:If the spill switch is activated and shuts off the main burner the following procedure

Seite 21 - ESTRICTIONS

Initial InstallationHEARTH MOUNT INSTALLATION:This unit may be installed as a hearth mounted unit.Install two 3’ inch pipes up the chimney to a seal p

Seite 22

29Initial InstallationGAS LINE CONNECTION AND TESTING:WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to

Seite 23

3Safety Precautions...2Table of Contents...

Seite 24

Initial InstallationELECTRICAL REQUIREMENTS:The ENVIRO ASCOT will operate without electrical power. This model has a millivolt gas control, which uses

Seite 25

31Secondary InstallationINSTALLATION OF LOG SET AND EMBERS:The placement of the logs is not arbitrary. If they are positioned incorrectly, the ames c

Seite 26

32Ledges for top right log.Figure 51. Log Placement Step 3.Secondary Installation3. A bag of ceramic ber embers and rock wool embers is provided g

Seite 27

INSTALLATION OF OPTIONAL BLOWER:Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your de

Seite 28

Trouble ShootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas c

Seite 29

35Parts ListReference NumberDescription Part Number1 120°F (49°C) Ceramic Fan Temperature Sensor EC-0012 S.I.T. Nova Valve Convertible 50-14213 Therm

Seite 30 - ELECTRICAL REQUIREMENTS:

Reference NumberDescription Part Number15 Electronic Ignition Module 50-589Dual Bulb Door Gasket (10 ft) 50-63416 Glass with Gasket 50-715Hinge pin -

Seite 31 - Placement pegs for

37ReferenceNumberCast Description Part Number20 Side panel (left)- Westport Green 50-06520 Side panel (left) - Antique Chestnut 50-85721 Cast ash she

Seite 32 - Secondary Installation

Parts DiagramASCOT - ComponentsDecember 200438

Seite 33

39WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to

Seite 34 - Trouble Shooting

4DIRECT VENT ONLY: This type is identied by the sufx DV. This appliance draws all of its air for combustion from outside the dwelling, through a spe

Seite 35 - Parts List

Warranty4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs o

Seite 36

4120. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials.

Seite 37

42Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Seite 38 - Parts Diagram

5SpecificationsDIMENSIONS:

Seite 39 - Warranty

Operating InstructionsFOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.LIGHTING INSTRUCTIONS:6CAUTION:Hot while operating. Do not touch. Keep children

Seite 40

2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the pie

Seite 41

8Maintenance And ServiceROUTINE MAINTENANCE:At least once a year, run through the following procedures to ensure the system is clean and working prope

Seite 42 - Installation Data Sheet

REPLACING GLASS:The glass in the replace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P