Westport
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any
open ame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbours phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas
supplier, call the re department.
WARNING: If the information in this manual is
not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of
life. Installation and service must be performed by a
qualied installer, service agency or the gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or
other ammable vapours and liquids in the vicinity of
this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or
gas tter when installed within the Commonwealth of Massachusetts. Other Massachusetts code
requirements: Flexible connector must not be longer than 36in., a shut off valve must be installed;
only direct vent sealed combustion products are approved for bedrooms/bathrooms. A carbon
monoxide detector is required in all rooms containing gas red direct vent appliances. The replace
damper must be removed or welded in the open position prior to installation of a replace insert.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - Westport

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Seite 2 - Safety Precautions

Figure 6: Handles for Removing Door. Figure 7: Removing of Door.Maintenance And ServiceRePLacing the gLass:The glass in the replace is a high tempera

Seite 3 - Table of Contents

11Using a ½" deep socket remove/reinstall the main burner orifice.Undo the two (2) screws that hold burner in the firebox.Rotate handles and remo

Seite 4 - Codes And Approvals

12Figure 9: Removing valve cap.Maintenance And Servicethe HI/LO knob by hand shown in Figure 9.Figure 11: Flip valve screw.Red o-ringis not visibleRed

Seite 5 - Specifications

Initial InstallationQUALIFIED INSTALLERS ONLYWARNING: Operation of this heater when not connected to a properly installed and maintained venting syste

Seite 6 - CAUTION:

Initial InstallationQUALIFIED INSTALLERS ONLYVertical TerminationStorm CollarFlashingRound Support Box/Wall ThimbleCeiling FirestopPipelengthPipeleng

Seite 7 - Operating Instructions

151 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.2 In accordance with the current ANSI Z223.1 NFPA 54, National

Seite 8

16Initial InstallationQUALIFIED INSTALLERS ONLYWirespacersFigure 19: Wire Spacers.it to the inner wall frame using four (4) 1½” wood screws.

Seite 9

Flue Pipe AdaptorWall FramingWall ThimbleFire StopExhaust 4" Flex PipeCombusion Air 6 5/8" Flex PipeWire SpacersHorizontal Vent TerminationI

Seite 10 - Maintenance And Service

18EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, D

Seite 11

12345View showing fully open restrictor plateView showing fully closed restrictor plate12345Figure 22: Restrictor plate settings.The ENVIRO WESTPORT h

Seite 12

2FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All ENVIRO gas-red appliances must b

Seite 13 - Initial Installation

Initial InstallationQUALIFIED INSTALLERS ONLYhoRizontaL instaLLation:1. Set the appliance in the desired location. Check to determine if wall studs or

Seite 14

21Initial InstallationQUALIFIED INSTALLERS ONLYWood screws (x4)Cut vinyl sidingaway to fit standoffBolt (x4)requiredNut (x4)requiredWoodscrew (x4)Figu

Seite 15

3. To install the Round Support Box/Wall Thimble in a at ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Fram

Seite 16

23the support straps that extend out beyond the edge of the ashing.7. Slip the ashing over the pipe section protruding through the roof. Secure the

Seite 17

plumber’s tapeconnected towall strapWall strap45° elbows (x2)NailsCeiling firestopCeilingSecond floorUse clearances to asdefined by appliance andvent

Seite 18

25Figure 36: Cathedral Ceiling Support Box Installation.Initial InstallationQUALIFIED INSTALLERS ONLY21/2”(67 mm)Inside WallOutside Wall36”(915 mm)Sno

Seite 19

Initial InstallationQUALIFIED INSTALLERS ONLYventing into a cLass ‘a’ chimney:This model is also certied and tested to vent into CLASS ‘A’ wood stove

Seite 20 - 10"

27Firebox TopFlue Collar AdapterUndo four ¼" screws that hold flue collar elbow to unit. Figure 40: Step 3 of Converting Top Vented into Rear Ven

Seite 21

Initial InstallationQUALIFIED INSTALLERS ONLYinstaLLation oF toP venteD; hoRizontaL teRmination:SidingExterior wallDrywallVent pipeInside finished col

Seite 22

29Initial InstallationQUALIFIED INSTALLERS ONLYFReestanDing DRaFthooD aDaPtoR - 50-841:This Drafthood Adaptor is a complete assembly and is ready to 

Seite 23 - Dimension ‘H’ obtained

Table of Contents3Safety Precautions...

Seite 24

The minimum clearance to combustibles is 6” (150 mm) when using single wall venting and 1” (25 mm) when using “B-vent” venting.We strongly recommend

Seite 25

31Initial InstallationAUTOMATIC SAFETY SHUT DOWN:If the spill switch is activated and shuts off the main burner the following procedure

Seite 26

Initial InstallationQUALIFIED INSTALLERS ONLYgas Line connection anD testing:WARNING: Only persons licensed to work with gas piping may make the neces

Seite 27

33Figure 51: Gas Control Valve and Optional Thermostat Wiring.Initial InstallationQUALIFIED INSTALLERS ONLYeLectRicaL RequiRements FoR gas vaLve anD o

Seite 28

Fan assemblyValve coverControl panel(Fan control location)Screw holeFigure 53: Optional Blower (Fan) Installation.Secondary InstallationinstaLLation o

Seite 29

351. Carefully remove logs from box. Check to ensure there is no damage. It is very important to install all logs in their proper position

Seite 30

Secondary InstallationCAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.Important note: When the unit is turned on for the rst

Seite 31

37Figure 63: Top brick panel in place, screws shown. Figure 64: Back brick panel in place.Figure 65: Side brick panels in place.Figure 62: Brick panel

Seite 32

38Trouble ShootingProblem Possible Cause SolutionThe main burner does not ignite when called for.The gas valve may not be on. • Check that the gas

Seite 33

39Reference NumberPart Description Part Number1 Top Vent Insert Piece - Painted EGWP-5031 Top Vent Insert Piece - Antique White EGWP-503AW1 Top Vent I

Seite 34 - Secondary Installation

4DIRECT VENT ONLY: This type is identied by the sux DV. This appliance draws all of its air for combustion from outside the dwelling, through a spec

Seite 35

Reference NumberPart Description Part Number5 Side Panel (Right) - Painted EGWP-5055 Side Panel (Right) - Antique White EGWP-505AW5 Side Panel (Right)

Seite 36

Reference NumberPart Description Part NumberTop Complete (Top, Vent Insert, & Grate) - Painted EGWP-501Top Complete (Top, Vent Insert, & Grate

Seite 37

42Parts Diagram - Cast12345768WESTPORT - CastingsJanuary 2005

Seite 38 - Trouble Shooting

Parts List - ComponentsReference NumberPart Description Part Number9 120° Ceramic Fan Temperature Sensor EC-00110S.I.T. Nova Valve Convertible 50-142

Seite 39 - Parts List - Cast

Parts List - ComponentsReference NumberPart Description Part Number19 Inner Door Handles (2 per set) 30-05220 Venturi Adjustment Rod 30-05321 Firebox

Seite 40

45Parts Diagram - Components13171610271526249221121252920141923122818WESTPORT - ComponentsJanuary 2005

Seite 41

46WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the h

Seite 42 - Parts Diagram - Cast

47caused by mechanical systems such as furnaces, fans, clothes dryers etc.12. The Limited Warranty is void if: a) The stove has been operated in atmo

Seite 43 - Parts List - Components

48Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Seite 44

5SpecificationsWARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxid

Seite 45 - Parts Diagram - Components

6Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCT

Seite 46 - Warranty

72. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several

Seite 47

8Operating InstructionsFor Your Safety, Read Safety Precautions And Lighting Instructions Before OperatingRemote contRoLs (oPtionaL):This replace can

Seite 48 - Installation Data Sheet

Electronic ignition moduleMaintenance And ServiceRoutine maintenance:At least once a year, run through the following procedures to ensure the system i