SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER ACCENT 25BV By SHERWOOD
7. INSTALLATION OF LOGS, EMBERS and BRICK PANELS INSTALLING THE GLOWING EMBERS and LOGSET A bag of ceramic fiber embers is provided for use on the bu
8.OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RES
9. ROUTINE MAINTENANCE and SERVICE Periodically check to ensure that your system is clean. Periodically check the pilot and burner. Check to see tha
10.FUEL CONVERSION “Warning” This conversion kit shall be installed by a qualified service technician in accordance with the manufacturer’s instruct
11. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not arc to the pilot after repeated pressing of spark ignitor Defective piezo igni
15 12. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer. PART # DESCRIPTION EG25-001 Convection Blower EG25-002 H
PAINTED DOOR EG25-092 BLACK IRON NIPPLE EG25-062 LOUVER SET (TOP & BOTTOM)EG25-115 FULLY ASSEMBLED PILOT EC-015 NG EC-016 LP THERMOPILE EC-012 TH
17FPI WIRING HARNESS PART (A) EC-034 (NOT SHOWN) FAN CONTROLLER EC-039 ACCENT 25 REGULAR SURROUND WITH TRIM PAINTED TRIM 50-107 BRASS TRIM 5
13. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of sev
14. INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference. Envirogas Model
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: •
TABLE OF CONTENTS SECTION PAGE 1. Code Approvals 3 2. Dimensions and Clearances to Combustibles 5 3. Venting 6 4. Assembly and Installation In
CODES AND APPROVALS CONTINUED RE: CONVERSION OF ZERO CLEARANCE FACTORY BUILT FIREPLACES The following instructions cover Sherwood Industries Ltd. po
2. DIMENSIONS AND CLEARANCES TO COMBUSTIBLES DISTANCE TO COMBUSTIBLES: Mantel pillar to surround panel 2" / 5.08 cm Floor to 8" wide man
3.VENTING FIREPLACE INSERTS WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in
4. ASSEMBLY AND INSTALLATION INSTRUCTIONS ASSEMBLING AND INSTALLING YOUR ENVIROGAS ACCENT 25 1. Remove the unit from it’s box 2. Open the door, b
5. ELECTRICAL REQUIREMENTS The ACCENT 25 will operate without electrical power. This model has a Millivolt gas control which uses the pilot flame to
6. GAS LINE CONNECTIONS and TESTING WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.